The purpose of the CDR valve is to maintain 0 to 0.996 kPa
(0-4 in. of water) vacuum in the crankcase at all engine speeds,
     assuming that the piston/ring  combustion blow by is not excessive (less
    than  4 cm). Too little vacuum  will tend to force oil leaks.
 The CDR valve is checked with a water manometer. The U-tube manometer
indicates pressure or vacuum by the difference in the height of the two columns
      of fluid.
 If the crankcase vacuum is more than 0.996 kPa (4 in.
of water), dirt or dust can be pulled into the crankcase cavity through the
     front/rear crankcase seal, etc. and contaminate the oil. If  the crankcase
     pressure is positive, engine oil leaks are likely  to occur around the
 engine     seals and the gaskets.
- Connect one end of the manometer to the engine oil dipstick hole.
The other end of the manometer is vented to the atmosphere.
 
- Unplug the rubber vent tube from the turbo inlet elbow.
 
- Run the engine through a no-load speed range (gear selector in
PARK) and observe the manometer readings. If the manometer reading is +0.996 kPa
    (+4 in. of water) or less positive pressure, reconnect the CDR
system     and proceed to  step 4. If the manometer reading is higher than
+0.996 kPa     (+4 in. of water) positive  pressure, this indicates
that there  is    an internal engine problem.
 
- Install the air cleaner.
 
- Start the engine and observe the manometer (vacuum) reading. The
manometer reading should be approximately 0.249 kPa (0-1 in.
    of water) at the idle to approximately 0.747-1.245 kPa (3-5 in
    of water) at 2000 RPM. Add the amount that the manometer column travels
  up,    to the amount that the column travels down, in order to obtain the
  total   water  pressure (vacuum).