Removal Procedure
- Remove the air cleaner assembly and duct work. Refer to 
Air Cleaner Assembly Replacement 
.
 
- Remove the electrical
connector from the ESO solenoid.
 
Important: Remove any debris from the ESO mounting surfaces on the injection pump
before servicing the ESO Solenoid. This will prevent contaminate intrusion
    into the injection pump.
- Remove the ESO solenoid.
 
Installation Procedure
- Install the new O-ring
on the ESO solenoid.
 
Notice: Refer to Component Fastener Tightening Notice in the Preface section.
- Install the
ESO solenoid in the injection pump.
 
Tighten
Tighten the solenoid (external hex or internal hex) to 25 N·m
(19 lb ft).
- Install the ESO electrical connector.
 
- Install the air cleaner assembly and duct work. Refer to 
Air Cleaner Assembly Replacement 
.
 
- Start engine and check for leaks.