Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
DEFINITION: The front blower motor will not operate in medium-1 speed only.  | ||||
1  | Did you review the HVAC blower operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | 
 Does the blower motor operate?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate?  | --  | Go to Step 6  | Go to Step 4  | 
4  | 
 Is continuity present?  | --  | Go to Step 5  | Go to Step 7  | 
5  | Repair the open in CKT 63 (TAN) between the heater and A/C controller connector and the blower motor resistor/relay connector. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 8  | --  | 
6  | Replace the blower motor resistor/relay. Refer to Blower Motor Resistor Replacement . Did you complete the repair?  | --  | Go to Step 8  | --  | 
7  | Replace the heater and A/C controller. Refer to Control Assembly Replacement . Did you complete the repair?  | --  | Go to Step 8  | --  | 
8  | Operate the blower motor in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |