Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC air delivery operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | 
 Does the rear auxiliary mode valve move and the air temperature change from hot to cold?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.  | Go to Step 3  | 
3  | 
 Did the test lamp light?  | --  | Go to Step 4  | Go to Step 6  | 
4  | 
 Did the test lamp light?  | --  | Go to Step 5  | Go to Step 7  | 
5  | Connect a J 39200 digital multimeter (DMM) between rear auxiliary temperature valve assembly connector cavity 10 for CKT 150 (BLK) and ground. Refer to Circuit Testing in Wiring Systems. Is continuity present?  | --  | Go to Step 8  | Go to Step 9  | 
6  | Repair the open in CKT 341 (BRN) between the instrument panel fuse block and the front auxiliary control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 10  | --  | 
7  | Repair the open in CKT 341 (BRN) between splice S405 and the instrument panel fuse block. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 10  | --  | 
8  | Replace the front auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front Is the repair complete?  | --  | Go to Step 10  | --  | 
9  | Repair the open in CKT 150 (BLK) between splice S411 and ground G400. Refer to Wiring Repairs Is the repair complete?  | --  | Go to Step 10  | --  | 
10  | Operate the rear HVAC system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |