Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Review the IP compartment lamp operation and perform the necessary inspections. Did you complete the system review and inspection?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Attempt to operate the IP compartment lamp. Does the lamp operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Is the measurement equal to battery voltage?  | B+  | Go to Step 5  | Go to Step 4  | 
4  | Repair the open CKT 40 (ORN) between the IP compartment lamp connector and the CTSY fuse. Did you complete the repair?  | --  | Go to Step 8  | --  | 
5  | At the IP ccompartment lamp connector, test the continuity between ground and cavity B of the IP compartment lamp connector. Is continuity present?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Repair the open CKT 150 (BLK). Did you complete the repair?  | --  | Go to Step 8  | --  | 
7  | Replace the IP compartment lamp switch. Did you complete the repair?  | --  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |