Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
DEFINITION: Both vanity mirrors are inoperative, but the stepwell lamps (which are operated by the same fuse) are operating properly.  | ||||
1  | Review the sun shade mirror lamp operation and perform the necessary inspections. Did you complete the system review and inspection?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Ensure that the left sun shade mirror lamp brightness adjustment is not at the minimum. Attempt to operate the sun shade mirror lamp. Does the system operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Is the measurement equal to battery voltage?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Repair the open CKT 40 (ORN) between splice S308 and the sunshade mirror lamp. Did you complete the repair?  | B+  | Go to Step 8  | --  | 
5  | Test continuity between ground and cavity B of the sunshade mirror lamp connector. Did the test indicate continuity?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Repair the open CKT 150 (BLK) between splice S204 and the sunshade mirror lamp. Did you complete the repair?  | --  | Go to Step 8  | --  | 
7  | Replace the sunshade mirror lamp bulb. Did you complete the repair?  | --  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |