Removal Procedure
- Disconnect the mass air flow (MAF) harness connector.
 
- Remove the air cleaner assembly hold down screw.
 
- Loosen the air cleaner outlet duct hose clamp.
 
- Remove the air cleaner assembly.
 
Installation Procedure
- Install the air cleaner assembly.
 
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the air cleaner outlet duct hose clamp.
 
Tighten
Tighten the air cleaner outlet duct hose clamp to 4 N·m (35 lb in).
- Install the air cleaner assembly hold down screw.
 
- Connect the MAF harness connector.