Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is inoperative in all speed positions.  | |||
1  | Did you review the HVAC operation and perform the necessary inspections?  | Go to Step 2  | |
2  | 
 Is the auxiliary blower motor inoperative in all speed positions?  | Go to Step 4  | Go to Step 3  | 
3  | 
 Is the auxiliary blower motor inoperative in all speed positions?  | Go to Step 9  | |
4  | 
 Does the test lamp illuminate?  | Go to Step 5  | Go to Step 6  | 
5  | 
 Does the test lamp illuminate?  | Go to Step 11  | Go to Step 13  | 
6  | Test the auxiliary blower motor supply voltage circuit for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 7  | 
7  | Test the ignition 3 voltage circuit for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 8  | 
8  | Test the battery positive voltage circuit to the auxiliary blower motor relays for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 9  | 
9  | Test the applicable blower motor speed control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 10  | 
10  | Test the ground circuit of the auxiliary blower motor switch, auxiliary heat only, or front auxiliary HVAC control assembly, auxiliary heat and A/C, for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 12  | 
11  | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 14  | 
12  | Inspect for poor connections at the harness connector of the auxiliary blower motor switch, auxiliary heat only, or front auxiliary HVAC control assembly, auxiliary heat and A/C. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 15  | 
13  | Repair the ground circuit of auxiliary blower motor for an open. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | 
14  | Replace the auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement . Did you complete the replacement?  | Go to Step 16  | --  | 
15  | Replace the auxiliary blower motor switch, auxiliary heat only, or the front auxiliary HVAC control assembly, auxiliary heat and A/C. Refer to Auxiliary Blower Motor Switch Replacement or Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement?  | Go to Step 16  | --  | 
16  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |