| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. | 
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. | 
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. | 
Circuit  | Short to Ground  | High Resistance  | Open  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|---|
APP Sensor 1 - 5-Volt Reference  | P0107, P0698, P2122, P2564  | P2138  | P2122  | P0106, P0699, P2123, P2227, P02565  | --  | 
MAP Sensor - 5-Volt Reference  | P0107, P0698, P2564  | P0101  | P0107  | P0106, P0401, P0699, P003A, P2565  | --  | 
TC Vane Position Sensor - 5-Volt Reference  | P0107, P0698, P2564  | P2563  | P2564  | P0106, P0401, P0699, P2565  | --  | 
EGR Valve - 5-Volt Reference  | P0107, P0698, P2564  | P046C  | P0405  | P0106, P0401, P0699, P2565  | --  | 
These 5-volt reference circuits are independent of each other outside the engine control module (ECM), but are bussed together inside the ECM. Therefore, a circuit condition on one sensor 5-volt reference circuit may affect the other sensor 5-volt reference circuits. The ECM monitors the voltage on the 5-volt reference circuit.
| • | The ignition is ON. | 
| • | Diagnostics run continuously. | 
| • | The ECM detects the 5-volt reference 3 circuit voltage is less than 4.7 volts. | 
| • | The above condition is present for 2 seconds. | 
| • | The ECM detects the 5-volt reference 3 circuit voltage is more than 5.2 volts. | 
| • | The above condition is present for 2 seconds. | 
DTCs P0698 and P0699 are Type A DTCs.
DTCs P0698 and P0699 are Type A DTCs.
Engine starts and runs.
Important: Additional DTCs will set when disconnecting the components.
Important: A short to voltage on the signal circuit of certain components may cause this DTC to set.
| ⇒ | If the voltage is less than the specified range, test for a short to ground on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. | 
| ⇒ | If the voltage is greater than the specified range, test for a short to voltage on all the 5-volt reference circuits. If all circuits test normal, replace the ECM. | 
| ⇒ | If the voltage display increases greater than the specified value when a component is connected, test the signal circuit for a short to voltage. If all circuits test normal, replace the ECM. | 
| ⇒ | If the voltage display decreases more than the specified value when a component is connected, replace the component. | 
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
| • | Control Module References for ECM replacement, setup, and programming |