Condition 
 | Corrective Action 
 | 
Clean Oil no debris present 
 | No corrective action necessary. 
 | 
Clean Oil with debris present 
 | 
|     •  | Inspect the suction port of the replacement compressor for presence of a suction screen. If the Replacement Compressor does NOT contain a suction screen, Install Suction Screen in the line. |  
  
|     •  | Replace desiccant or component containing the desiccant. |  
  
|     •  | Replace desiccant filter if applicable. |  
  
|     •  | Remove and inspect high pressure side filter (if applicable). |  
  
|     •  | Remove, inspect, clean, or replace orifice tube. |  
  
|     •  | If the system has a front orifice tube and is equipped with a filter in the rear auxiliary line, remove, inspect, clean, or replace the filter. |  
  
|     •  | If the system has a front orifice tube and is not equipped with a filter in the rear auxiliary line, remove the filter in the auxiliary TXV and Install a universal inline A/C Filter P/N 89016656 (AC Delco P/N 15-10413) as close to the rear TXV as
possible. |  
  
 | 
Dark brown/black and/or pungent/unusual odor with no debris present 
 | 
|     •  | Replace desiccant or component containing the desiccant.  |  
  
|     •  | Replace desiccant filter if applicable.  |  
  
|     •  | Flush refrigerant system. |  
  
 | 
Dark brown/black and/or pungent/unusual odor with debris present 
 | 
|     •  | Replace desiccant or component containing the desiccant. |  
  
|     •  | Replace desiccant filter if applicable. |  
  
|     •  | Flush refrigerant system.  |  
  
|     •  | Inspect the suction port of the replacement compressor for presence of a suction screen. If the replacement compressor does NOT contain a suction screen, install suction screen. |  
  
|     •  | Remove and inspect high pressure side filter (if applicable).  |  
  
|     •  | Remove, inspect, clean, or replace orifice tube. |  
  
|     •  | If the system has a front orifice tube and is equipped with a filter in the rear auxiliary line, remove, inspect, clean, or replace the filter.  |  
  
|     •  | If the system has a front orifice tube and is not equipped with a filter in the rear auxiliary line, remove the filter in the auxiliary TXV and install a universal inline A/C Filter P/N 89016656 (AC Delco P/N 15-10413) as close to the rear TXV as
possible. |  
  
 | 
Oil Overcharge 
 | Flush refrigerant system. 
 | 
Refrigerant Contamination 
 | Flush refrigerant system. 
 | 
Hybrid Polyolester Refrigerant Oil (POE) Contamination 
 | 
|     •  | Flush refrigerant system. |  
  
|     •  | Replace desiccant or component containing the desiccant. |  
  
|     •  | Replace desiccant filter if applicable. |  
  
 |