Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Remove the upper fan shroud. Refer to 
Engine Coolant Fan Upper Shroud Replacement.
 
- Remove the drive belt. Refer to 
Drive Belt Replacement.
 
- Disconnect the auxiliary generator electrical connector.
 
- Remove the positive cable from the auxiliary generator, perform the following:
 
| 4.1.  | Slide the boot down to access the terminal stud. | 
 
| 4.2.  | Remove the positive cable nut. | 
 
| 4.3.  | Remove the positive cable. | 
 
- Remove the auxiliary generator bolts (3).
 
- Remove the auxiliary generator (4).
 
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Position the auxiliary generator (4).
 
- Install the auxiliary generator bolts (3) and tighten to 
50 N·m (37 lb ft).
 
- Install the positive cable to the auxiliary generator, perform the following:
 
| 3.1.  | Position the positive cable. | 
 
| 3.2.  | Install the positive cable nut and tighten to 
10 N·m (89 lb in). | 
 
| 3.3.  | Slide the boot to cover the terminal stud. | 
 
- Connect the generator electrical connector.
 
- Install the drive belt. Refer to 
Drive Belt Replacement.
 
- Install the upper shroud. Refer to 
Engine Coolant Fan Upper Shroud Replacement.