Special Tools
J 39400-A  Halogen Leak Detector
Removal Procedure
- Disconnect the low pressure switch electrical connector (2).
 
- Remove the low pressure switch (1) from the accumulator.
 
- Remove the O-ring seal.
 
Installation Procedure
- Install the new O-ring seal to the switch. Refer to 
O-Ring Replacement.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C low pressure switch (1) to the accumulator and tighten to
4 N·m (35 lb in).
 
- Connect the low pressure switch electrical connector  (2).
 
- Leak test the fittings of the component using the 
J 39400-A .