Important: Before attempting the Fuel Tank Leak Check place a dry chemical (Class
B) fire extinguisher near the work area.
- Install the J 41415-40 
 fill tank cap adaptor.
 
- Connect the J 41413 
 EVAP pressure/purge diagnostic station to the fill tank cap adaptor.
 
- With a scan tool, seal the EVAP system.
 
- Raise the vehicle on a hoist. Refer to 
Vehicle Lifting Caution 
.
 
- With the EVAP diagnostic station, maintain 15 inches H2O
(3.75 kPa) within the fuel tank.
 
Important: It may be necessary to partially lower the fuel tank to inspect the
top of the fuel tank and fuel sender assembly O-ring. Refer to 
Fuel Tank Replacement 
.
- With the J 41416 
ultrasonic leak detector, test for leaks in the fuel tank and EVAP pipes.
 
- Visually inspect for fuel leaking from the fuel tank.
 
- If a leak is detected refer to the following component replacements: