Heater Pipes Replacement RPO LS4
                    Tools Required
J 38185 
 Hose Clamp Pliers
Removal Procedure
- Remove the air cleaner assembly. Refer to 
Air Cleaner Assembly Replacement
 .
 
- Drain the cooling system. Refer to 
Cooling System Draining and Filling
 .
 
- Release and reposition the heater inlet and outlet hose clamps using the 
J 38185 
 .
 
Important: Cap or plug the cooling components to prevent system contamination.
- Remove the heater hoses from heater pipes.
 
Notice: Do not apply excessive force on the heater core pipes during hose removal.
Applying excessive force on the heater core pipes may damage the heater core
pipes.
- Remove the heater pipe assembly retaining bolts from the rear the of engine.
 
- Remove the heater pipe assembly retaining bolt from the front of the engine.
 
- Release and reposition the heater pipe hose clamps at the engine using the 
J 38185 
 .
 
- Remove the heater pipe hoses from the engine.
 
- Remove the heater pipe assembly from the vehicle.
 
Installation Procedure
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the heater pipe assembly at the
engine and heater hoses.
 
- Install the heater pipe assembly into position in the vehicle.
 
- Install the heater pipe hoses to the engine.
 
- Reposition and release the heater pipe hose clamps at the engine using the 
J 38185 
 .
 
- Loosely install the heater pipe assembly retaining bolt to the front of the engine.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the heater pipe assembly retaining bolts to the rear of the engine.
 
Tighten
Tighten all the heater pipe assembly bolts to 16 N·m (12 lb ft).
- Connect heater hoses to the heater pipe assembly.
 
- Install the heater hose clamps into position using the 
J 38185 
 .
 
- Install the air cleaner assembly. Refer to 
Air Cleaner Assembly Replacement
 .
 
- Fill the cooling system. Refer to 
Cooling System Draining and Filling
 .
 
                            Heater Pipes Replacement RPOs LZE, LZ4, LZ9
                    
Callout 
 | Component Name 
 | 
| 
 Notice: Refer to Fastener Notice in the Preface section. Fastener Tightening Specifications:
 Refer to 
Fastener Tightening Specifications
 . 
 Preliminary Procedure
- Drain the cooling system. Refer to 
Cooling System Draining and Filling
 .
 
- Remove heater inlet hose from the heater pipe assembly. Refer to 
Heater Inlet Hose Replacement
.
 
- Remove heater outlet hose from the heater pipe assembly. Refer to 
Heater Outlet Hose Replacement
.
 
- Remove the air cleaner duct. Refer to 
Air Cleaner Resonator Outlet Duct Replacement
.
 
 
 | 
1 
 | Nut, Pipe Assembly - Heater Inlet and Outlet Pipe - Left 
Tighten 10 N·m (89 lb in)  | 
2 
 |  Pipe Assembly, Heater Inlet and Outlet Pipe - Left 
Tip Using the 
J 38185 
 disconnect the left heater pipe assembly from the front heater pipe assembly.  | 
3 
 | Bolt, Pipe Assembly - Heater Inlet and Outlet Pipe - Front 
Tighten 25 N·m (18 lb in)  | 
4 
 | Stud, Pipe Assembly - Heater Inlet and Outlet Pipe - Front 
Tighten 10 N·m (89 lb in)  | 
5 
 |  Pipe Assembly, Heater Inlet and Outlet Pipe - Front  
 |