Problem  | Action  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Excessive leakage  | Check the compressor unloaders, governor, and air dryer check valve.  | ||||||||||
The purge control line exhibits one of following conditions: 
 
 
 
 
  | Determine if the air flows through the purge control line when the air compressor is unloaded. Repair or replace as needed.  | ||||||||||
Governor malfunction  | Inspect the control lines to and from the governor for restrictions. Use a calibrated external gage in the supply reservoir, service reservoir, or reservoir port of the governor to verify cut-in and cut-out pressures. If governor is malfunctioning, replace it.  | ||||||||||
The air brake dryer purge valve is faulty.  | Replace the purge valve.  |