Special Tools
J 39400-A  Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the air conditioning (A/C) system. Refer to 
Refrigerant Recovery and Recharging.
 
- Remove the right wheelhouse panel. Refer to 
Wheelhouse Panel Replacement.
 
- Remove the air cleaner. Refer to the appropriate procedure:
 
- Disconnect the low pressure sensor electrical connector.
 
- Disconnect the blower motor assembly electrical connector.
 
- Disconnect the blower motor resistor assembly electrical connector.
 
- Remove the accumulator. Refer to 
Air Conditioning Accumulator Replacement.
 
- Remove the multi-use module bracket. Refer to the appropriate procedure:
 
| •  | Caterpillar® 3126 Unit Repair Manual | 
 
- Remove the retaining nut (3) from the evaporator inlet tube (5).
 
- Remove the evaporator inlet tube from the evaporator.
 
- Remove the sealing washer.
 
- Remove the retaining nut (4) from the evaporator outlet tube (3).
 
- Remove the evaporator outlet tube from the evaporator.
 
- Remove the sealing washer.
 
- Remove the front cover retaining screws from the evaporator and blower module assembly.
 
- Remove the front cover.
 
- Remove the evaporator core from the evaporator and blower module assembly.
 
Installation Procedure
- Add polyalkylene glycol (PAG) oil to the evaporative emission (EVAP) core. Refer to 
Refrigerant System Capacities.
 
- Install the evaporator core to the evaporator and blower module assembly.
 
- Install the front cover.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the front cover retaining screws to the evaporator and blower module assembly.
 
Tighten
Tighten the screws to 6 N·m (53 lb in).
- Install new O-ring seals to the evaporator inlet and outlet tubes. Refer to 
O-Ring Replacement.
 
- Install the evaporator inlet tube to the evaporator.
 
- Install the evaporator inlet tube retaining nut (3).
 
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the evaporator outlet tube to the evaporator.
 
- Install the evaporator outlet tube retaining nut.
 
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the multi-use module bracket. Refer to the appropriate procedure:
 
| •  | Caterpillar® 3126 Unit Repair Manual | 
 
- Install the accumulator. Refer to 
Air Conditioning Accumulator Replacement.
 
- Connect the low pressure sensor electrical connector.
 
- Connect the blower motor assembly electrical connector.
 
- Connect the blower motor resistor assembly electrical connector.
 
- Install the air cleaner. Refer to the appropriate procedure:
 
- Install the right wheelhouse panel. Refer to 
Wheelhouse Panel Replacement.
 
- Evacuate and recharge the A/C system. Refer to 
Refrigerant Recovery and Recharging.
 
- Leak test the fittings of the components using the 
J 39400-A .