Problem 
 | Action 
 | 
Excessive system leakage is evident. 
 | 
- Inspect for system leakage. 
 
- Repair the system.
 
 
 | 
Excessive leakage is evident in one or more of the following components: 
|     •  | The tubing connected to the compressor |  
  
|     •  | The main supply reservoir |  
  
 | 
- Test the system for leakage at the following components:
 
| •  | The safety valve in the air dryer |  
  
- Repair or replace as needed.
 
 
 | 
The internal check valve is faulty. 
 | 
- Remove the check valve from the assembly from the end cover.
 
- Apply air pressure to the delivery side of the valve. 
 
- Apply a soap solution at the opposite end.
 
- Inspect for leakage. Permissible air leakage per single connection is 50 sccm (standard cubic centimeters per minute), which is approximately equivalent to s single 1 inch diameter soap bubble in 10 seconds.
 
- If the leakage is excessive, replace the check valve.
 
 
 | 
The governor is faulty. 
 | 
- Inspect the governor for proper cut-in and cut-out pressures.
 
- Inspect the governor for excessive leakage in both positions. Refer to 
Air Compressor and Governor Valve Diagnosis
 .
 
 
 | 
The compressor unloader mechanism is leaking. 
 | 
- Remove the air inlet hose and the fitting from the air compressor inlet cavity. 
 
- Inspect for leakage in the unloader piston while the air compressor is unloaded. Slight leakage is permissible.
 
 
 |