Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Wiper/Washer Schematics Connector End View Reference: Wiper/Washer Connector End Views DEFINITION: The low washer fluid indicator is always ON or does not turn ON with low washer fluid.  | |||
1  | Did you review the Wiper/Washer System Description and Operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify the fault is present. Does the system operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Does the low washer fluid indicator remain illuminated with the ignition ON?  | Go to Step 6  | Go to Step 4  | 
4  | 
 Does the low washer fluid indicator remain illuminated with the ignition ON?  | Go to Step 5  | Go to Step 7  | 
5  | 
 Does the low washer fluid indicator remain illuminated with the ignition ON?  | Go to Step 9  | Go to Step 8  | 
6  | Test the washer fluid level switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 13  | Go to Step 11  | 
7  | Test the washer fluid level switch signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 13  | Go to Step 11  | 
8  | Repair the washer fluid level switch ground circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Is the repair complete?  | Go to Step 13  | --  | 
9  | Inspect for poor connections at the washer fluid level switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 13  | Go to Step 10  | 
10  | Replace the washer fluid level switch. Is the repair complete?  | Go to Step 13  | --  | 
11  | Inspect for poor connections at the instrument panel cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 13  | Go to Step 12  | 
12  | Replace the IPC. Refer to Control Module References for replacement, setup, and programming. Is the repair complete?  | Go to Step 13  | --  | 
13  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |