Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Headlights/Daytime Running Lights (DRL) Schematics Connector End View Reference: Master Electrical Component List  | |||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |||||||
2  | 
 Do the DRLs illuminate?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | ||||||
3  | Is the brake warning indicator illuminated?  | Go to Step 4  | |||||||
4  | 
 Does the test lamp illuminate?  | Go to Step 5  | Go to Step 11  | ||||||
5  | 
 Do the DRLs illuminate?  | Go to Step 6  | Go to Step 12  | ||||||
6  | 
 Does the test lamp illuminate?  | Go to Step 7  | Go to Step 13  | ||||||
7  | Connect a test lamp between the ignition 1 voltage circuit of the DRL relay and the DRL relay control circuit of the DRL relay. Does the test lamp illuminate?  | Go to Step 9  | Go to Step 8  | ||||||
8  | Test the DRL relay control circuit for the following: 
 
 
 Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 10  | ||||||
9  | Inspect for poor connections at the DRL relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 14  | ||||||
10  | Inspect for poor connections at the harness connector of the DRL control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 15  | ||||||
11  | Repair an open, high resistance or short to ground in the DRL diode supply voltage circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | ||||||
12  | Repair an open, high resistance or short to ground in the headlamp low beam supply voltage circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | ||||||
13  | Repair an open, high resistance or short to ground on the ignition 1 voltage circuit of the DRL relay. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | ||||||
14  | Replace the DRL relay. Refer to Relay Replacement . Did you complete the replacement?  | Go to Step 16  | --  | ||||||
15  | Replace the DRL control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 16  | --  | ||||||
16  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||