Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics or HVAC Vacuum Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets.  | |||
1  | Did you review the HVAC operation and perform the necessary inspections?  | Go to Step 2  | |
2  | 
 Is the blower motor OFF?  | Go to Step 3  | Go to Blower Motor Always On  | 
3  | Place the blower motor switch in each speed position. Does the blower motor operate at all?  | Go to Step 4  | Go to Blower Motor Inoperative  | 
4  | Does the blower motor operate correctly for each speed position?  | Go to Step 5  | Go to Blower Motor Malfunction  | 
5  | Test the Ignition 3 voltage circuit of the vacuum pump assembly for an open, high resistance or short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 6  | 
6  | Test the ground circuit of the vacuum pump assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 7  | 
7  | Disconnect the vacuum hose going to the vacuum pump. Does the vacuum pump turn ON?  | Go to Step 8  | |
8  | Inspect for poor connections at the harness connector of the vacuum pump assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 9  | 
9  | Replace the vacuum pump assembly. Refer to Vacuum Pump Assembly Replacement . Did you complete the replacement?  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 1  |