Important: When replacing a failed compressor, inspect the expansion orifice tube for material build up. Clean or replace as necessary. Refer to Expansion (Orifice) Tube Replacement .
| 11.1. | Drain the oil from both the suction and the discharge ports into a clean container. |
| 11.2. | Remove the compressor crankcase oil drain plug and drain the crankcase oil into the same container. |
| 11.3. | Measure and record the amount of oil drained from the compressor. This measurement will be used during the compressor installation procedure. |
| 11.4. | Properly discard the used PAG oil. |
Important: NEW A/C compressors are shipped WITHOUT poly-alkylene glycol (PAG) oil. Use of the incorrect PAG oil can result in compressor failure.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the drain bolt (1) to 20 N·m (15 lb ft).
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
Tighten
Tighten the bolt to 33 N·m (24 lb ft).