| • | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. | 
| • | Review Strategy Based Diagnosis for an overview of the diagnostic approach. | 
| • | Diagnostic Procedure Instructions provides an overview of each diagnostic category. | 
The starter/generator control module (SGCM) monitors the performance to detect 12-volt DC wire electrical failure by comparing the 12-volt input to the 12-volt output values. If the difference is greater than 5 volts, the DTC sets.
| • | The engine is running. | 
| • | Hybrid mode is active. | 
The 12-volt power supply - 12-volt output voltage is greater than 5 volts for 119 ms and any fault during 15 seconds wait period.
| • | Stop PWM (MGU shutdown). | 
| • | APM PWM off. | 
Cycle wake up signal.
Possible 12-volt battery or APM voltage sensor stuck.
Starter/Generator Description and Operation
Control Module References for scan tool information
| ⇒ | If the DTC resets, replace the SGCM. | 
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming