Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Turn the ignition switch to the RUN position.
- Observe the instrument cluster gauges and indicators.
Do the instrument cluster gauges and indicators operate?
| --
| Go to
Step 5
| Go to
Step 2
|
2
| Inspect fuse 39 in the fuse block.
Is fuse 39 open?
| --
| Go to
Step 3
| Go to
Step 4
|
3
|
- Turn the ignition switch to the OFF position.
- Replace fuse 39.
- Turn the ignition switch to the RUN position.
- Inspect fuse 39 again.
Is fuse 39 open again?
| --
| Go to
Step 6
| Go to
Step 9
|
4
| Inspect the power feed to fuse 39 for the following
conditions:
Refer to Fuse Block Details for Schematic.
Is the symptom still present?
| --
| Go to
Step 9
| --
|
5
|
- Turn the ignition switch to the OFF position.
- Disconnect the remote control door lock receiver (RCDLR) connector.
- Use a test lamp in order to probe between the RCDLR harness connector
terminal J and ground.
- Turn the ignition switch to the RUN position, while observing
the test light.
Did the test lamp light?
| --
| Go to
Step 7
| Go to
Step 8
|
6
| Repair a short to ground in CKT 39.
Is the symptom still present?
| --
| Go to
Step 9
| --
|
7
|
- Inspect the RCDLR connector for poor terminal contact.
- Replace the RCDLR if the connector is OK. Refer to Keyless Entry
for RCDLR replacement procedures.
Is the symptom still present?
| --
| Go to
Step 9
|
|
8
| Inspect for the following conditions
in CKT 39:
If conditions do not exist, then refer to Interior Lights.
| --
| Go to
Step 9
| --
|
9
|
- Ensure that the ignition switch is in the OFF position.
- Reconnect any connectors that you previously disconnected.
- Install any components that you previously removed.
Is the symptom still present?
| --
| Refer to
Headlight System Check
.
| --
|