Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
1 
 | 
- Disconnect the inoperative door lock actuator.
 
- Use a test light in order to probe between the inoperative door
lock actuator terminal B and the ground.
 
- While observing the test light, press the inoperative door lock
switch to the LOCK position.
 
 
Does the test light illuminate? 
 | -- 
 | 
Go to Step
2
     
 | 
Go to Step 3
     
 | 
2 
 | 
- Use a test light in order to backprobe between the inoperative
door lock actuator terminal A and the ground.
 
- While observing the test light, press the inoperative door lock
switch to the UNLOCK position.
 
 
Does the test light illuminate? 
 | -- 
 | 
Go to Step
4
     
 | 
Go to Step 5
     
 | 
3 
 | Repair the poor connection or an open in circuit 295 between
the inoperative  door lock actuator and S315. 
Is the repair complete? 
 | -- 
 | 
Go to Step
6
     
 | -- 
 | 
4 
 | 
- Inspect for a poor connection at the inoperative door lock actuator.
 
- If the connection is OK, replace the inoperative door lock actuator.
 
 
Refer to 
Front Side Door Lock Actuator Replacement  
Is the repair complete? 
 | -- 
 | 
Go to Step
6
     
 | -- 
 | 
5 
 | Repair the poor connection or an open in circuit 294 between
the inoperative door lock actuator and S314. 
Is the repair complete? 
 | -- 
 | 
Go to Step
6
     
 | -- 
 | 
6 
 | 
- Ensure the ignition switch is in the LOCK position.
 
- Reconnect any connectors/components removed.
 
 
Have all repairs been made? 
 | -- 
 | Go to 
Power Door Locks System Check  
 | -- 
 |