Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Interior Lights Dimming Schematics  | |||
1  | Did you perform the Lighting System Diagnostic System Check?  | Go to Step 2  | |
2  | 
 Are all of the courtesy lamps OFF?  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | Remove the BATT rundown protection relay. Do the courtesy lamps turn OFF?  | Go to Step 6  | Go to Step 4  | 
4  | 
 Do the courtesy lamps turn OFF?  | Go to Step 7  | Go to Step 5  | 
5  | Repair a short to battery positive voltage on the courtesy lamps supply voltage. Refer to Wiring Repairs and to Connector Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 8  | --  | 
6  | Replace the BATT rundown protection relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement?  | Go to Step 8  | --  | 
7  | Replace the RH I/P fuse block. Refer to Instrument Panel Electrical Center or Junction Block Replacement - Right Side in Wiring Systems. Did you complete the replacement?  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |