Removal Procedure
- Remove the positive crankcase ventilation (PCV) valve tube (4) from the air cleaner intake duct.
 
- Disconnect the intake air temperature (IAT) sensor electrical connector (3).
 
- Disconnect the mass air flow (MAF) sensor electrical connector (5).
 
- Loosen the clamps (2,6) and remove the air cleaner intake duct with the MAF sensor from the throttle body and the air cleaner housing cover (8).
 
- Loosen the clamp and remove the MAF sensor from the air cleaner intake duct.
 
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the MAF sensor to the air cleaner intake duct.
 
Tighten
Tighten the clamp to 2 N·m (18 lb in).
- Install the air cleaner intake duct with the MAF sensor to the throttle body and the air cleaner housing cover (8).
 
Tighten
Tighten the clamps to 2 N·m (18 lb in).
- Connect the MAF sensor electrical connector (5).
 
- Connect the IAT sensor electrical connector (3).
 
- Install the PCV valve tube (4) to the air cleaner intake duct.
 
- Start and idle the engine.
 
- Inspect the air intake duct for leaks.