Removal Procedure
- Disassemble the A/C refrigerant components. Refer to the appropriate repair
procedure.
 
- Remove
the O-ring seals from the A/C refrigerant component.
 
- Inspect the O-ring seals for signs of damage.
 
- Inspect the A/C refrigerant components for damage or burrs. Repair if
necessary.
 
Important: Cap or tape the open A/C refrigerant components immediately to prevent system
contamination.
- Cap or tape the A/C refrigerant components.
 
- Discard the O-ring seals.
 
Installation Procedure
- Inspect the new O-ring seals for any sign or cracks, cuts, or damage.
Replace if necessary.
 
- Remove the cap or tape from the A/C refrigerant components.
 
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces
of the A/C refrigerant components.
 
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on
the new O-ring seal to enter the refrigerant system.
- Lightly coat the new O-ring seals with mineral base 525 viscosity refrigerant
oil.
 
Important: DO NOT reuse O-ring seals.
- Carefully slide the new O-ring seals onto the A/C refrigerant component.
 
- The O-ring seals must be fully seated.
 
- Assemble the A/C components.
 
Refer to the appropriate repair procedure.