| Table 1: | A/C Performance Table | 
This test measures the operating efficiency of the A/C system under the following conditions:
| • | The current ambient air temperature | 
| • | The current relative humidity | 
| • | The high side pressure of the A/C system | 
| • | The low side pressure of the A/C system | 
| • | The temperature of the air being discharged into the passenger compartment | 
The number(s) below refer to the step number(s) on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step  | Action  | Value(s)  | Yes  | No  | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 
 Important: 
  | ||||||||||||||||||||||||||||
 Are both the low and high side pressures within the specified value?  | Above 16°C (60°F) - 345 kPa (50 psi) Above 24°C (75°F) - 483 kPa (70 psi) Above 33°C (90°F) - 690 kPa (100 psi)  | Go to Step 2  | Go to Leak Testing  | |||||||||||||||||||||||||
 Important: Record the relative humidity and the ambient air temperature AT THE TIME OF THE TEST. 
 
 
 
 
 
 
 
 
 Important: When performing this step it is necessary to press the RESET button on the J 43600 before pressing the PRINT button. 
 
 
 Does all the data recorded fall within the specified ranges of the A/C performance table?  | --  | Go to Step 8  | Go to Step 3  | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges: 
 Does all the data recorded fall within the specified ranges of the A/C performance table?  | --  | Go to Step 8  | Go to Step 4  | |||||||||||||||||||||||||
4  | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not?  | --  | Go to Step 5  | |||||||||||||||||||||||||
5  | Is the low side pressure greater than the specified range, but the high side pressure is within or less than the specified range?  | --  | Go to Step 6  | |||||||||||||||||||||||||
6  | Are the low and high side pressures both greater than the specified ranges?  | --  | Go to Step 7  | |||||||||||||||||||||||||
7  | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range?  | --  | Go to Step 8  | |||||||||||||||||||||||||
8  | Operate the system in order to verify the test results. Did you find the same results?  | --  | System OK  | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual  | ||||||||||||||||||||||||
Ambient Air Temperature  | Relative Humidity  | Service Port Pressure  | Maximum Left Center Discharge Air Temperature  | |
|---|---|---|---|---|
Low Side  | High Side  | |||
13-18°C (55-65°F)  | 0-100%  | 175-239 kPa (25-35 psi)  | 920-1360 kPa (133-197 psi)  | 11°C (51.8°F)  | 
18-24°C (65-75°F)  | Below 40%  | 175-225 kPa (25-33 psi)  | 940-1360 kPa (136-197 psi)  | 9°C (48.2°F)  | 
Above 40%  | 175-256 kPa (25-37 psi)  | 1080-1480 kPa (157-215 psi)  | 12°C (53.6°F)  | |
24-29°C (75-85°F)  | Below 35%  | 175-238 kPa (25-35 psi)  | 1200-1510 kPa (174-219 psi)  | 11°C (51.8°F)  | 
35-50%  | 181-246 kPa (26-36 psi)  | 1260-1540 kPa (183-224 psi)  | 11°C (58.1°F)  | |
Above 50%  | 192-262 kPa (27-38 psi)  | 1310-1580 kPa (190-229 psi)  | 12°C (53.6°F)  | |
29-35°C (85-95°F)  | Below 30%  | 188-258 kPa (27-37 psi)  | 1400-1720 kPa (203-250 psi)  | 12°C (53.6°F)  | 
30-50%  | 196-262 kPa (28-38 psi)  | 1420-1720 kPa (206-250 psi)  | 13°C (55.4°F)  | |
Above 50%  | 206-268 kPa (30-40 psi)  | 1460-1720 kPa (212-250 psi)  | 13°C (55.4°F)  | |
35-41°C (95-105°F)  | Below 20%  | 214-282 kPa (31-41 psi)  | 1640-1950 kPa (238-283 psi)  | 14°C (57.2°F)  | 
20-40%  | 216-282 kPa (31-41 psi)  | 1640-1950 kPa (238-283 psi)  | 14°C (57.2°F)  | |
Above 40%  | 220-282 kPa (32-41 psi)  | 1640-1950 kPa (238-283 psi)  | 14°C (57.2°F)  | |
41-46°C (105-115°F)  | Below 20%  | 243-303 kPa (35-44 psi)  | 1890-2140 kPa (274-311 psi)  | 16°C (60.8°F)  | 
Above 20%  | 242-303 kPa (35-44 psi)  | 1890-2140 kPa (274-311 psi)  | 16°C (60.8°F)  | |
46-49°C (115-120°F)  | Below 30%  | 263-310 kPa (38-45 psi)  | 2060-2210 kPa (299-321 psi)  | 17°C (62.6°F)  |