Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
 
- Disconnect the vacuum hose from the exhaust gas recirculation (EGR) valve.
 
- Remove the EGR valve retaining bolts.
 
- Remove the EGR valve from the electronic ignition (EI) system ignition coil adapter.
 
Installation Procedure
- Clean the EI system ignition coil adapter mating surface.
 
- Install a new EGR valve gasket.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the EGR valve with the bolts.
 
Tighten
Tighten the exhaust gas recirculation valve retaining bolts to 30 N·m (22 lb ft).
- Connect the vacuum hose to the EGR valve.
 
- Connect the negative battery cable