Step  | Action  | Yes  | No  | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic References: Starting and Charging Schematics Connector End View References: Component Connector End Views  | |||||||||||
1  | Did you review the following description and operations and perform the necessary inspections?  | Go to Step 2  | |||||||||
2  | Turn the ignition to the START position. Did the starter solenoid click?  | Go to Step 3  | |||||||||
3  | Inspect the engine and belt drive system for mechanical binding--seized engine, seized generator. Does the engine move freely?  | Go to Step 4  | 
 
 
 
  | ||||||||
4  | Test the battery positive cable between the battery and the starter solenoid for high resistance. Refer to Circuit Testing or Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 5  | ||||||||
5  | Test the ground circuit between the battery and the starter motor for a high resistance. Refer to Circuit Testing or Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 6  | ||||||||
6  | Inspect for poor connections at the starter. Refer to Testing for Intermittent Conditions and Poor Connections or Connector Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 7  | ||||||||
7  | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement?  | Go to Step 8  | --  | ||||||||
8  | Operate the system for which the symptom occurred. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||||