Step  | Action  | Values  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the Battery Description and Operation , the Starting System Description and Operation , and the Charging System Description and Operation and perform the necessary inspections?  | --  | Go to Step 2  | |
2  | 
 Does the scan tool indicate the voltage is within the specified value?  | 11-15.5 V  | Go to Step 3  | Go to Battery Inspection/Test  | 
3  | 
 Is the generator output within 10 amps of the specified value?  | 85 A  | Go to Step 9  | Go to Step 4  | 
4  | 
 Is the voltage above the specified value?  | 0.5 V  | Go to Step 6  | Go to Step 5  | 
5  | 
 Is the voltage above the specified value?  | 0.5 V  | Go to Step 7  | Go to Step 8  | 
6  | Test the battery positive circuit between the generator output terminal and the battery positive terminal for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | --  | Go to Step 9  | Go to Step 7  | 
7  | Repair the high resistance in the ground circuit between the generator housing and the battery negative terminal. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair?  | --  | Go to Step 9  | --  | 
8  | Replace the generator. Refer to Generator Replacement . Did you complete the repair?  | --  | Go to Step 9  | --  | 
9  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |