Application 
 | Specification 
 | 
Metric 
 | English 
 | 
Starting System 
 | 
| 
 | 15.5 mm 
 | 0.610 in 
 | 
| 
 | 10.0 mm 
 | 0.394 in 
 | 
- Brush Spring Tension - Standard
 
 
 | 1.8-2.4 kg 
 | 4.0-5.3 lbs 
 | 
- Brush Spring Tension - Minimum
 
 
 | 1.2 kg 
 | 2.6 lbs 
 | 
- Commutator Insulation Depth - Standard
 
 
 | 0.60 mm 
 | 0.024 in 
 | 
- Commutator Insulation Depth - Minimum
 
 
 | 0.20 mm 
 | 0.008 in 
 | 
- Commutator Outside Diameter - Standard
 
 
 | 30 mm 
 | 1.18 in 
 | 
- Commutator Outside Diameter - Minimum
 
 
 | 29 mm 
 | 1.14 in 
 | 
- Commutator Runout - Standard
 
 
 | 0.05 mm 
 | 0.002 in 
 | 
| 
 | Clockwise (as viewed from pinion) 
 | 
| 
 | 9 
 | 
| 
 | 1.4 watts 
 | 
| 
 | 30 seconds 
 | 
- Starter Current Draw, no load
 
 
 | 90 amps at 11.5 volts 
 | 
- Starter Current Draw, load, manual transaxle (9.1 N·m/80.5 lb in
    of torque)
 
 
 | 300 amps at 7.7 volts 
 | 
- Starter Current Draw, load, automatic transaxle (10.4 N·m/92 lb in
 of torque)
 
 
 | 300 amps at 7.7 volts 
 | 
- Locked Rotor - Manual Transaxle (18.6 N·m/13.8 lb ft)
 
 
 | 780 amps at 4 volts 
 | 
- Locked Rotor - Automatic Transaxle (25.5 N·m/18.8 lb ft)
 
 
 | 980 amps at 4 volts 
 | 
- Starter Solenoid Operating Voltage
 
 
 | 8 volts minimum 
 | 
- Solenoid Contact Plate Wear - Maximum
 
 
 | 0.9 mm 
 | 0.035 in 
 | 
| 
 | 12 volts 
 |