Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the DLC System Check performed?  | --  | Go to Step 2  | |
2  | Was the SIR Diagnostic System Check performed?  | --  | Go to Step 3  | Go to SIR Diagnostic System Check in SIR  | 
3  | Inspect for proper connection of the scan tool to the data link connector at terminal 9. Is the connection good?  | --  | Go to Step 4  | Go to Step 14  | 
4  | 
 Is the connection good?  | --  | Go to Step 5  | Go to Step 14  | 
5  | 
 Is the resistance greater than the specified value?  | 0.5 ohms  | Go to Step 6  | Go to Step 8  | 
6  | Connect a DMM between SDM terminal 5 and DLC terminal 9. Is the resistance less than the specified value?  | 3 ohms  | Go to Step 15  | Go to Step 10  | 
7  | 
 Is the voltage within the specified range?  | 0-5 V  | Go to Step 9  | Go to Step 11  | 
8  | Repair the short to ground in CKT 800. Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
9  | 
 Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
10  | Repair the open in CKT 800. Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
11  | Disconnect the VIU. Is the voltage within the specified range?  | 0-5 V  | Go to Step 12  | Go to Step 13  | 
12  | Replace the VIU. Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
13  | 
 Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
14  | Repair the connection as needed. Is the repair complete?  | --  | Go to SIR Diagnostic System Check in SIR  | --  | 
15  | 
 Is the resistance less than the specified value?  | 3 ohms  | Go to Step 7  | Go to Step 10  |