Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Instrument Cluster System Check?  | --  | Go to Step 2  | |||||
2  | 
 Are the temperatures approximately equal or within 25°?  | 87°C (190°F)  | Go to Step 3  | Go to Step 6  | ||||
3  | Read the monitored coolant temperature from the scan tool. Is the monitored coolant temperature reading within the specified range?  | 38-127°C 100-260°F)  | Go to Step 4  | Go to Step 5  | ||||
4  | Compare the monitored coolant temperature with the displayed coolant temperature. Are the temperatures approximately equal or within 11°C (25°F)?  | --  | Go to Step 5  | Go to Step 6  | ||||
5  | 
 
 Is the gauge reading correct?  | --  | Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls - 2.2L Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls - 4.3L  | Go to Step 6  | ||||
6  | Replace the IP cluster. Refer to Instrument Cluster Replacement . Is the repair complete?  | --  | --  |