Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did you review the charging system operation and perform the necessary inspections?  | --  | ||||||
2  | Verify that the charge indicator is always on. Does the charge indicator operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | |||||
3  | Using the scan tool, inspect for any DTCs. Are any DTCs present?  | --  | Go to the Appropriate DTC  | |||||
4  | 
 Do all of the indicator bulbs turn ON and OFF properly?  | --  | Go to Diagnostic System Check - Instrument Cluster in Instrument Panel, Gauges and Console  | |||||
5  | Disconnect the generator connector. Is the battery indicator still ON?  | --  | ||||||
6  | 
 
 
 Is continuity present?  | --  | ||||||
7  | Repair the short to ground Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |||||
8  | Using the J 39200 DMM, measure the voltage at the battery stud on the generator. Is the voltage within the specified range?  | 9-16 V  | ||||||
9  | Repair or replace the generator Refer to Generator Replacement . Is the repair complete?  | --  | --  | |||||
10  | Repair the open in CKT 2 (RED) Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |||||
11  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  |