Compressor Control Switches Removal HT6/HD6/HU6
                    
Tools Required
|     •  | J 43600  ACR 2000
 Air Conditioning Service Center | 
 
- Recover the refrigerant
using the J 43600 
.
 
- Disconnect the electrical connector from the switch (2)
in the rear head of the compressor.
 
- Remove the switch retaining ring using the J 5403 
.
 
- Remove the switch (2) from the compressor.
 
- Remove the old O-ring seal from the switch cavity using the J 9553-01 
.
 
- Inspect the switch cavity and the O-ring groove in the rear head
for dirt or foreign material. Clean the components as necessary.