Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the seat belt circuit description and perform the necessary inspections?  | --  | Go to Step 2  | |
2  | Verify that the fasten safety belt indicator is inoperative. Does the fasten safety belt indicator operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | Was the instrument panel cluster (IPC) system check performed?  | --  | Go to Step 4  | Go to Diagnostic System Check - Instrument Cluster in Instrument Panel, Gages and Console  | 
4  | 
 Does the seat belt lamp turn ON and OFF when commanded?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 5  | 
5  | Replace the IPC. Refer to Instrument Cluster Replacement in Instrument Panel, Gages and Console. Is the repair complete?  | --  | Go to Step 6  | --  | 
6  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |