In the ON position, the ignition switch applies battery voltage to the AIR BAG warning lamp and to the IGNITION 1 input terminal 10. The inflatable restraint sensing and diagnostic module (SDM) responds by flashing the AIR BAG warning lamp 7 times. The SDM monitors the lamp driver output by comparing the output state at the AIR BAG INDICATOR CONTROL terminal 7 to the microprocessor commanded state.
The output state at the INFLATABLE RESTRAINT INDICATOR terminal 7 does not match the commanded state of the lamp driver for 400 milliseconds.
The CONTINUOUS MONITORING test inspects for this DTC. This test occurs when IGNITION 1 is within the normal operating voltage range.
| • | The SDM sets a diagnostic trouble code. | 
| • | The SDM attempts to turn ON the AIR BAG warning lamp. | 
| • | Current DTC--The output state at the INFLATABLE RESTRAINT INDICATOR terminal 7 matches the commanded state of the lamp driver for 400 milliseconds. | 
| • | History DTC | 
| - | You issue a scan tool CLEAR CODES command. | 
| - | After 250 malfunction free ignition cycles have occurred. | 
Refer to AIR BAG Warning Lamp Comes On Steady and AIR BAG Warning Lamp Does Not Come On to diagnose warning lamp circuit malfunctions.
Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Was the SIR Diagnostic System Check performed?  | --  | Go to Step 2  | |||||
2  | 
 
 
 Is DTC B1061 set?  | --  |