Accessory Mounting Brackets Replacement PS Pump
                    
Removal Procedure 
- Remove the air cleaner
outlet duct. Refer to 
Air Cleaner Outlet Duct Replacement 
 in  Engine Controls.
 
- Remove the engine cooling fan. Refer to 
Fan Clutch Replacement 
 in Engine Cooling.
 
- Remove the drive belt. Refer to 
Drive Belt Replacement 
 
Important: Do not evacuate the air conditioning system.
- Remove the mounting bolts for the air conditioning (A/C) compressor,
if equipped.
 
- Move the A/C compressor aside and support.
 
- Remove the drive belt idler pulley if not equipped with A/C. Refer
to 
Drive Belt Idler Pulley Replacement 
.
 
- Remove the power steering pump pulley. Refer to 
Power Steering Pump Replacement 
 in Power
Steering Systems.
 
- Remove the three bolts
holding the power steering pump to the power steering pump mounting bracket.
 
- Remove the three bolts
and nut holding the power steering pump mounting bracket to the engine.
 
- Slide the bracket off the power steering mounting bracket stud
and power steering pump.
 
Installation Procedure
- Slide the power steering
pump mounting bracket onto the stud and the power steering pump.
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the power
steering pump mounting bracket three bolts and the nut.
 
Tighten
Tighten the power steering pump mounting bracket bolts and nut to 41 N·m
(30 lb ft).
- Install the three bolts
for the power steering pump.
 
Tighten
Tighten the power steering pump to power steering pump mounting bracket
bolts to 50 N·m (37 lb ft).
- Install the power steering pump pulley. Refer to 
Power Steering Pump Replacement 
 in Power
Steering Systems.
 
- Install the air conditioning compressor, if equipped. Refer to 
Air Conditioning Compressor Replacement 
 in
Heating Ventilation and Air Conditioning.
 
- Install the drive belt idler pulley if not equipped with A/C.
Refer to 
Drive Belt Idler Pulley Replacement 
.
 
- Install the drive belt. Refer to 
Drive Belt Replacement 
.
 
- Install the engine cooling fan. Refer to 
Fan Clutch Replacement 
 in Engine Cooling.
 
- Install the air cleaner outlet duct. Refer to 
Air Cleaner Outlet Duct Replacement 
 in Engine Controls.
 
                            Accessory Mounting Brackets Replacement Generator
                    
Removal Procedure
- Disconnect the battery
negative cable. Refer to 
Battery Replacement 
  in Engine Electrical.
 
- Remove the engine cooling fan. Refer to 
Fan Clutch Replacement 
 in Engine Cooling.
 
- Remove the drive belt. Refer to 
Drive Belt Replacement 
.
 
- Remove the generator. Refer to 
Generator Replacement 
 in Engine Electrical.
 
- Remove the engine wiring harness bracket from the generator mounting
bracket.
 
- Remove the drive belt tensioner. Refer to 
Drive Belt Tensioner Replacement 
 
- Remove the drive belt idler pulley. Refer to 
Drive Belt Idler Pulley Replacement 
.
 
- Remove the three bolts
and nut holding the generator mounting bracket to the engine.
 
- Slide the generator mounting bracket off of the stud.
 
Installation Procedure
- Slide the generator mounting
bracket onto the stud. 
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the two
generator mounting bracket bolts and the nut.
 
Tighten
Tighten the generator mounting bracket bolts and nut to 41 N·m
(30 lb ft).
- Install the drive belt idler pulley. Refer to 
Drive Belt Idler Pulley Replacement 
.
 
- Install the drive belt tensioner. Refer to 
Drive Belt Tensioner Replacement 
.
 
- Install the engine wiring
harness bracket to the generator mounting bracket.
 
Tighten
Tighten the engine wiring harness bracket bolt to 25 N·m
(18 lb ft).
- Install the generator. Refer to 
Generator Replacement 
 in Engine Electrical.
 
- Install the drive belt. Refer to 
Drive Belt Replacement 
.
 
- Install the engine cooling fan. Refer to 
Fan Clutch Replacement 
 in Engine Cooling.
 
- Connect the battery negative cable. Refer to 
Battery Replacement 
 in Engine Electrical.