Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the HVAC system operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | Verify that the temperature control is inoperative. Does the temperature control operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | Inspect the HVAC I fuse 21. Is the fuse open?  | --  | Go to Step 21  | Go to Step 4  | 
4  | 
 Does the voltage vary smoothly and continuously within the specified range?  | 0-12 V  | Go to Step 5  | Go to Step 10  | 
5  | Using the J 35616-A , connect a J 39200 DMM between cavity 10 (CKT 341) of the air temperature valve motor connector and ground. Does the voltage equal the specified value?  | B+  | Go to Step 6  | Go to Step 8  | 
6  | Using the J 35616-A , connect a J 39200 DMM between cavity 10 (CKT 341) and cavity 7 (CKT 1850) of the air temperature valve motor connector. Does the voltage equal the specified value?  | B+  | Go to Step 7  | Go to Step 9  | 
7  | Replace the air temperature valve motor. Refer to Temperature Actuator Replacement . Is the repair complete?  | --  | Go to Step 26  | --  | 
8  | Locate and repair the open or high resistance in CKT 341 between the IP fuse block HVAC I fuse 21 and air temperature valve motor. Is the repair complete?  | --  | Go to Step 26  | --  | 
9  | Locate and repair the open or high resistance in CKT 1850 between the air temperature valve motor and G200. Is the repair complete?  | --  | Go to Step 26  | --  | 
10  | Did the voltage remain at or near the specified value regardless of the temperature control knob position?  | B+  | Go to Step 11  | Go to Step 16  | 
11  | 
 Does the voltage equal the specified value?  | B+  | Go to Step 12  | Go to Step 13  | 
12  | Replace the heater controller/heater and A/C controller. Refer to Control Assembly Replacement . Is the repair complete?  | --  | Go to Step 26  | --  | 
13  | Move the headlamp switch to the OFF position. Does the voltage equal the specified value?  | B+  | Go to Step 14  | Go to Step 15  | 
14  | Locate and repair the high resistance in CKT 1050 between splice pack SP203 and G203. Is the repair complete?  | --  | Go to Step 26  | --  | 
15  | Locate and repair the open or high resistance in CKT 1050 between the heater controller/heater and A/C controller connector C3 terminal C and splice pack SP203. Is the repair complete?  | --  | Go to Step 26  | --  | 
16  | Did the voltage remain at or near the specified value regardless of the temperature control knob position?  | 0 V  | Go to Step 17  | Go to Step 11  | 
17  | 
 Does the voltage vary smoothly and continuously within the specified range?  | 0-12 V  | Go to Step 18  | Go to Step 19  | 
18  | Repair the open or high resistance in CKT 733 between the heater controller/heater and A/C controller and the air temperature valve sensor. Is the repair complete?  | --  | Go to Step 26  | --  | 
19  | Using the J 39200 , backprobe at the heater controller/heater and A/C controller connector C3 terminal A and terminal C in order to measure the voltage drop. Does the voltage equal the specified value?  | B+  | Go to Step 24  | Go to Step 20  | 
20  | Using the J 39200 , backprobe at the heater controller/heater and A/C controller connector C3 terminal A and ground in order to measure the voltage drop. Does the voltage equal the specified value?  | B+  | Go to Step 12  | Go to Step 8  | 
21  | Using the J 39200 DMM, probe the HVAC I fuse 21 test points. Does the J 39200 DMM display the specified value at both test points?  | B+  | Go to Step 22  | Go to Step 23  | 
22  | Locate and repair the short to ground in CKT 341 between the IP fuse block and the heater controller/heater and A/C controller connector C3 terminal A. Is the repair complete?  | --  | Go to Step 26  | --  | 
23  | Locate and repair the open in CKT 300 between the IP fuse block and the ignition switch. Refer to Power Distribution Schematics in Wiring Systems. Is the repair complete?  | --  | Go to Step 26  | --  | 
24  | 
 Does the voltage vary smoothly and continuously within the specified range?  | 0-12 V  | Go to Step 25  | Go to Step 12  | 
25  | Repair the short to ground in CKT 733 between the heater controller/heater and A/C controller connector C3 terminal B and the air temperature valve sensor. Is the repair complete?  | --  | Go to Step 26  | --  | 
26  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |