Removal Procedure
- Remove the instrument
 panel accessory trim plate. Refer to 
Instrument Panel Accessory Trim Plate Replacement 
 in  Instrument  Panel, Gages  and 
  Console.
 
- Remove the HVAC control module retaining screws.
 
- Depress the HVAC control module retaining tabs and remove the
 HVAC control module from the instrument panel.
 
- Disconnect the electrical connectors from the HVAC control module.
 
- Remove the HVAC control module bulb from the HVAC control module
 and retain.
 
Installation Procedure
- Install the HVAC control module bulb to the HVAC control module.
 
- Connect the electrical
 connectors to the HVAC control module.
 
- Install the HVAC control module into the instrument panel, ensuring
 that the HVAC control module retaining tabs lock into place.
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HVAC  control module retaining screws.
 
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the instrument panel accessory trim plate. Refer to 
Instrument Panel Accessory Trim Plate Replacement 
 in Instrument
 Panel,  Gages and Console.