Cooling Fan Relay Replacement Low Speed
                    
Removal Procedure
- Remove the condenser fan low relay nut (1).
 
- Lift the relay (2) and harness connector (3) up and disconnect
the relay (2).
 
Installation Procedure
- Install the condenser fan low relay (2)
into the harness connectors (3).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the relay (2) onto the mounting stud and install
the nut (1).
 
Tighten
Tighten the nut to 6 N·m (53 lb in).
                            Cooling Fan Relay Replacement High Speed
                    
Removal Procedure
- Remove the condenser fan high relay nut (1).
 
- Lift the relay (2) and harness connector (3) up and disconnect
the relay (2).
 
Installation Procedure
- Install the condenser fan high relay (2)
into the harness connectors (3).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the relay (2) onto the mounting stud and install
the nut (1).
 
Tighten
Tighten the nut to 6 N·m (53 lb in).