Condition  | Action  | 
|---|---|
Low fluid level  | Add fluid to the proper level. Refer to Transmission Fluid Check .  | 
Air leak in oil suction filter canister  | Replace the oil suction filter. Refer to Oil Pan Replacement .  | 
Clogged suction filter  | Replace the filter. Refer to Oil Pan Replacement .  | 
Aerated fluid causes noisy pump  | Correct the fluid level. Refer to Transmission Fluid Check .  | 
Low main pressure causes main regulator valve to oscillate  | Refer to Low Main Line Pressure in All Ranges and Low Main Line Pressure in Specific Ranges, Normal Pressure in Other Ranges .  |