Step
| Action
| Value(s)
| Yes
| No
|
1
| Has the Heater Blower Controls System Check been performed?
| --
| Go to
Step 2
| Go to
Heater Blower Controls System Check
|
2
|
- Place the ignition switch in the RUN position.
- Place the blower switch in the M1 position, next to the LO position.
- Disconnect the connector at the blower resistor.
- Connect a DMM (volts) between the blower resistor connector, cavity C,
and ground.
Is battery voltage present?
| --
| Go to
Step 4
| Go to
Step 3
|
3
|
- Disconnect connector C2 at the HVAC control module.
- Connect a DMM (continuity) between pins B and G of the
HVAC control module connector C2.
- Turn the blower switch to the Med1 position (next to the Low position).
Is there continuity?
| --
| Go to
Step 6
| Go to
Step 5
|
4
| Replace the blower motor resistor. Refer to
Blower Motor Relay Replacement
.
Is the repair complete?
| --
| Go to
Heater Blower Controls System Check
| --
|
5
| Replace the HVAC control module. Refer to
Blower Switch Replacement
.
Is the repair complete?
| --
| Go to
Heater Blower Controls System Check
| --
|
6
| Locate and repair the open in CKT 63 (TAN) between
the HVAC control module and the blower resistor. Refer to
Wiring Repairs
in Wiring Systems.
Is the repair complete?
| --
| Go to
Heater Blower Controls System Check
| --
|