Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION : This diagnostic should be
used only when the window is operative from the master power window switch
and inoperative from the individual power window switch.
|
1
| Has the
Power Window System Check been performed?
| --
| Go to
Step 2
| Go to
Power Windows System Check
|
2
|
- Place the ignition switch in the RUN position.
- Place the window lockout switch in the normal position.
- Connect a test lamp between CKT 1307 (DK BLU) and
ground at the appropriate power window switch connector.
Does the test lamp light?
| --
| Go to
Step 3
| Go to
Step 4
|
3
|
- Inspect the appropriate power window switch connector for a faulty
connection.
- If the connection is OK, replace the appropriate power window
switch. Refer to
Power Accessory Switch Panel Replacement
or
Rear Side Door Window Switch Replacement
.
Is the repair complete?
| --
| Go to
Power Windows System Check
| --
|
4
| Repair the open in CKT 1307 (DK BLU) between the appropriate
power window switch connector and the window lockout switch. Refer to
Wiring Repairs
.
is the repair complete?
| --
| Go to
Power Windows System Check
| --
|