| Table 1: | BCM Scan Tool Data List | 
| Table 2: | HVAC Control Module Scan Tool Data List | 
| Table 3: | PCM Scan Tool Data List | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
Left Solar Sensor  | Data  | Counts  | Varies  | 
Right Solar Sensor  | Data  | Counts  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Switch  | Input/Output  | On, Off  | Off  | 
AC Permission  | Input/Output  | Withheld, Granted  | Varies  | 
Air Inlet Door Actual  | Door Positions  | Counts  | Varies  | 
Air Inlet Door Commanded  | Door Positions  | Counts  | Varies  | 
Air Inlet Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Air Mix Door Left Commanded  | Door Positions  | Counts  | Varies  | 
Air Mix Door Right Commanded  | Door Positions  | Counts  | Varies  | 
Auto Switch  | Input/Output  | On, Off  | Off  | 
Battery Voltage  | Input/Output  | Volts  | 13.5-14.5 V  | 
Blower Motor PWM Speed  | Input/Output  | Percent  | 12-114%  | 
Coolant Pump  | Input/Output  | ON/ OFF  | OFF  | 
Dim Level Requested  | Sensor Data  | Percent  | Varies  | 
DTM Difference Minimum  | Sensor Data  | Counts  | 2 Counts  | 
Engine Coolant Temp  | Sensor Data  | °C/°F  | Varies  | 
Engine Request  | Input/Output  | Received/ Not Received  | Not Received  | 
Engine Request Priority  | Input/Output  | Priority 1/ Priority 2  | Priority 1  | 
Fan Down Button  | Input/Output  | On, Off  | Off  | 
Fan Up Button  | Input/Output  | On, Off  | Off  | 
Front Defrost Switch  | Input/Output  | On, Off  | Off  | 
Ign. Since Current DTC  | Input/Output  | Numeric  | 0  | 
Inside Air Temp.  | Sensor Data  | °C/°F  | Varies  | 
Inside Air Temp. Fan  | Sensor Data  | On, Off  | On  | 
Left Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Left Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Left Temp. Setting  | Input/Output  | °C/°F  | Varies  | 
LH AC Duct Actual  | Sensor Data  | Counts  | Varies  | 
LH AC Duct Desired  | Sensor Data  | Counts  | Varies  | 
LH Heater Duct Actual  | Sensor Data  | Counts  | Varies  | 
LH Heater Duct Desired  | Sensor Data  | Counts  | Varies  | 
Mode Select Position  | Door Positions  | Off, Auto, Defrost, Heater, Htr/Def, Bi-level, Panel  | Varies  | 
Mode Door Actual  | Door Positions  | Counts  | Varies  | 
Mode Dr. Motor Command  | Door Positions  | Counts  | Varies  | 
Mode Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Mode Switch  | Input/Output  | On, Off  | Off  | 
Off Switch  | Input/Output  | On, Off  | Off  | 
Outside Air Temp. Filtered  | Input/Output  | °C/°F  | 22-27°C (70-80°F)  | 
Outside Air Temp. Raw  | Input/Output  | °C/°F  | Varies  | 
Pressure Cycle Switch  | Input/Output  | Low Pressure, Normal  | Varies  | 
Rear Defrost Switch  | Input/Output  | On, Off  | Off  | 
Recirculate Switch  | Input/Output  | On, Off  | Off  | 
RH AC Duct Actual  | Sensor Data  | Counts  | Varies  | 
RH AC Duct Desired  | Sensor Data  | Counts  | Varies  | 
RH Heater Duct Actual  | Sensor Data  | Counts  | Varies  | 
RH Heater Duct Desired  | Sensor Data  | Counts  | Varies  | 
Right Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Right Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Right Temp. Setting  | Input/Output  | °C/°F  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Pressure Sensor  | Engine Data 2  | kPa, Psi  | 629-845 kPa (85-120 psi)  | 
A/C Pressure Sensor  | Engine Data 2  | Volts  | Varies  | 
A/C Relay Command  | Engine Data 2  | On, Off  | Varies  | 
A/C Request Signal  | Engine Data 2  | Yes, No  | Varies  | 
ECT Sensor  | Engine Data 2  | °C/°F  | 92°C (197°F)  | 
ECT Sensor  | Engine Data 2  | Volts  | 1.10-1.45 Volts  |