Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
1 
 | 
- Inspect the routing of the cable for a kink, wiring interference
or instrument panel interference.
 
- Repair the cable as necessary.
 
 
Did you find and correct a condition? 
 | -- 
 | Go to 
Step 2
              
 | System OK 
 | 
2 
 | 
- Disconnect the cable from the temperature valve. Refer to 
Temperature Control Cable Replacement 
.
 
- Manually cycle the valve.
 
- Inspect the valve for binding.
 
 
Does the valve bind? 
 | -- 
 | Go to 
Step
3
               
 | Go to 
Step
4
                   
 | 
3 
 | 
- Inspect the valve seals for proper installation.
 
- Repair the valve seals as necessary.
 
 
Did you find and correct a condition? 
 | -- 
 | System OK 
 | Go to 
Step 7
                
 | 
4 
 | Inspect the control for binding. 
Does the control bind? 
 | -- 
 | Go to 
Step
5
               
 | Go to 
Step
8
                   
 | 
5 
 | 
- Disconnect the cable from the control assembly.
 
- Retest the control for binding.
 
 
Does the control bind? 
 | -- 
 | Go to 
Step
6
               
 | Go to 
Step
9
                   
 | 
6 
 | Replace the control. Refer to 
Control Assembly Replacement 
. 
Is the repair complete? 
 | -- 
 | System OK 
 | -- 
 | 
7 
 | 
- Inspect the temperature valve for misalignment of the shaft, a
bent shaft or valve, and a warped case.
 
- Repair the temperature valve as necessary.
 
 
Is the repair complete? 
 | -- 
 | System OK 
 | -- 
 | 
8 
 | 
- Reconnect the cable to the temperature valve.
 
- Reinspect the clearance of the cable around the instrument panel
components.
 
 
Is the repair complete? 
 | -- 
 | System OK 
 | -- 
 | 
9 
 | Replace the cables as necessary. Refer to 
Temperature Control Cable Replacement 
. 
Is the repair complete? 
 | -- 
 | System OK 
 | -- 
 |