Removal Procedure
Important: Clean the evaporative emission (EVAP) line connections and surrounding areas prior to disconnecting the fittings in order to avoid possible EVAP system contamination.
- Remove the fuel tank. Refer to 
Fuel Tank Replacement.
 
- Remove the fuel tank shield retainers (2, and 3) and shields (1, and 4).
 
- Remove the EVAP lines from the fuel tank clips (2, and 6).
 
- Open the fuel tank clips (1, 3, 4, and 5) and remove the EVAP lines from the clips.
 
- Disconnect the EVAP line quick connect fittings at the fuel tank module and vent valve. Refer to 
Plastic Collar Quick Connect Fitting Service.
 
- Remove the EVAP lines from the fuel tank.
 
Installation Procedure
- Install the EVAP lines to the fuel tank.
 
- Connect the EVAP line quick connect fittings at the fuel tank module and vent valve. Refer to 
Plastic Collar Quick Connect Fitting Service.
 
- Install the EVAP lines to the fuel tank clips (1, 3, 4, and 5) and close the clips.
 
- Install the EVAP lines to the fuel tank clips (2, and 6).
 
- Install the fuel tank shields (1, and 4) and retainers (2, and 3).
 
- Install the fuel tank. Refer to 
Fuel Tank Replacement.