Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement Non-HP2
                    Special Tools
J 39400-A  Halogen Leak Detector
Removal Procedure
- Disconnect the electrical connector from the A/C refrigerant pressure sensor.
 
- Remove the A/C refrigerant pressure sensor (1) from the condenser tube.
 
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C refrigerant pressure sensor (1).
 
Tighten
Tighten the switch to 6 N·m (53 lb in).
- Connect the electrical connector to the A/C refrigerant pressure sensor.
 
- Leak test the fittings of the components using the 
J 39400-A .
 
- Lower the vehicle.
 
                            Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement HP2
                    
Callout 
 | Component Name 
 | 
 Preliminary Procedures
- Disconnect the electrical connector from the pressure sensor.
 
- Remove the upper radiator air baffle.
 
 
 | 
1 
 | A/C Refrigerant Pressure Sensor 
Caution: Refer to Fastener Caution in the Preface section. 
Tip Remove and discard the O-ring. Refer to 
O-Ring Replacement. 
Tighten 6 N·m (53 lb in)  |