Step  | Action  | Yes  | No  | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: The low side pressure is higher than normal and the high side pressure is lower than normal. 
 
  | |||||||||||
1  | Were you sent here from the A/C System Performance Test?  | Go to Step 2  | |||||||||
2  | After continued operation of the air conditioning (A/C) system, do the low and the high side pressures equalize or become static?  | Go to Step 5  | Go to Step 3  | ||||||||
3  | Refer to the pressures recorded during the A/C System Performance Test. Inspect for the following conditions: Warning: Refer to Moving Parts and Hot Surfaces Warning in the Preface section. 
 
 
 
 Do the listed conditions exist?  | Go to Step 5  | Go to Step 4  | ||||||||
4  | Refer to the pressures recorded during the A/C System Performance Test. Inspect for the following conditions: Warning: Refer to Moving Parts and Hot Surfaces Warning in the Preface section. 
 
 
 
 Do the listed conditions exist ?  | Go to Step 5  | |||||||||
5  | The A/C system has a low refrigerant charge. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging. Is the procedure complete?  | Go to Step 6  | --  | ||||||||
6  | 
 Are the readings within the specified ranges found on the A/C Performance Chart?  | Go to Step 13  | Go to Step 7  | ||||||||
7  | The A/C compressor is malfunctioning. Remove the expansion device and inspect for contamination. Refer to Expansion (Orifice) Tube Replacement. Did you find metal flakes on the expansion device?  | Go to Step 9  | Go to Step 8  | ||||||||
8  | Inspect the expansion device for a brown, powdery residue indicating desiccant in the A/C system. Is a brown, powdery residue present?  | Go to Step 11  | Go to Step 12  | ||||||||
9  | 
 Is metal flake contamination present?  | Go to Step 10  | Go to Step 12  | ||||||||
10  | 
 Is the repair complete?  | Go to Step 13  | --  | ||||||||
11  | 
 Is the repair complete?  | Go to Step 13  | --  | ||||||||
12  | 
 Is the repair complete?  | Go to Step 13  | --  | ||||||||
13  | Operate the system in order to verify the repair. Did you find and correct the condition?  | System OK  | |||||||||